Bioluminescence and fluorescence for small animal imaging
In vivo bioluminescence and in vivo fluorescence imaging each offer distinct advantages for small animal imaging applications.
In vivo bioluminescence imaging (BLI)
Uses luciferase-based reporters that deliver low background signals from animal tissues, offering high sensitivity, high specificity, and quantifiable results. The technique is easy to use and capable of detecting and monitoring disease progression such as tumors deep within tissue.
Uses luciferase-based reporters that deliver low background signals from animal tissues, offering high sensitivity, high specificity, and quantifiable results. The technique is easy to use and capable of detecting and monitoring disease progression such as tumors deep within tissue.
In vivo fluorescence imaging (FLI)
Is a powerful in vivo optical imaging modality that allows you to visualize and quantify biological targets, pathways, and processes across a range of experimental models. In vivo fluorescence imaging utilizes fluorescent reporters such as proteins, dyes, or nanoparticles, which emit photons when excited at a specific wavelength to produce light. Whether your biology focus is to monitor cellular or genetic activity, track gene expression, track disease progression, or evaluate the effect of new drug candidate, Revvity offers a wide range of in vivo fluorescence imaging systems to meet your research requirements.
Is a powerful in vivo optical imaging modality that allows you to visualize and quantify biological targets, pathways, and processes across a range of experimental models. In vivo fluorescence imaging utilizes fluorescent reporters such as proteins, dyes, or nanoparticles, which emit photons when excited at a specific wavelength to produce light. Whether your biology focus is to monitor cellular or genetic activity, track gene expression, track disease progression, or evaluate the effect of new drug candidate, Revvity offers a wide range of in vivo fluorescence imaging systems to meet your research requirements.
Optical reagents
Obtain more information from your target and get more insightful research results with our wide-range of imaging reagents. Built around your applications our optical reagents are optimized for use on our full range of IVIS in vivo imaging systems, including:
- IVISense fluorescent agents, labeling kits, dyes and panels
- IVISbrite bioluminescent substrates
- IVISbrite luciferase labeled oncology cell lines and bacteria
Obtain more information from your target and get more insightful research results with our wide-range of imaging reagents. Built around your applications our optical reagents are optimized for use on our full range of IVIS in vivo imaging systems, including:
- IVISense fluorescent agents, labeling kits, dyes and panels
- IVISbrite bioluminescent substrates
- IVISbrite luciferase labeled oncology cell lines and bacteria
Featured products
Which IVIS system is best for your research?
|
|
|
|
|
| IVIS Lumina S5 | IVIS Lumina X5 | IVIS Spectrum 2 | IVIS SpectrumCT 2 | |
| Capacity | Up to 10 mice* | Up to 10 mice* | Up to 10 mice* | Up to 10 mice* |
| Benchtop format | ✔ | ✔ | ||
| 2D Bioluminescence / Fluorescence | ✔/✔ | ✔/✔ | ✔/✔ | ✔/✔ |
| 3D Bioluminescence / Fluorescence | ✔/✔ | ✔/✔ | ||
| Enhanced Fluorescence capabilities | ✔ | ✔ | ✔ | ✔ |
| Integrated standard x-ray | ||||
| Integrated high resolution x-ray | ✔ | |||
| Integrated CT | ✔ | |||
| Spectral Unmixing | ✔ | ✔ | ✔ | ✔ |
| 3D Multimodal Co-Registration | ✔ | ✔ | ||
| Optical FOV (cm) (Nominal) | 10–22.5 | 10–22.5 | 4–22.5 | 4–22.5 |
| Wavelength range (nm) | 410–865 | 410–865 | 415–850 | 415–850 |
| NIST Calibration | ✔ | ✔ | ✔ | ✔ |
| Relative Cost | $$$$$ | $$$$$ | $$$$$ | $$$$$ |
Please contact your sales representative for more detailed information on our IVIS optical imaging systems.
*Using optional manifold kit
**Using expansion lens
Featured resources
FAQs
-
How do I know which IVIS system is right for my research?
Choosing the right IVIS optical imaging platform depends on your specific experimental needs. Key factors include whether you need 2D or 3D tomographic imaging, single-mode or multimode detection, and your throughput requirements. Revvity offers a range of IVIS systems, from entry-level platforms for straightforward bioluminescence studies to advanced integrated systems for complex, multi-parameter experiments.
-
Can IVIS optical imaging systems be integrated into my existing lab workflow?
Yes. The IVIS in vivo optical imaging platform is designed with workflow flexibility in mind. They can be used as standalone imaging systems or integrated with complementary tools such as anesthesia systems, heated stages, and analysis software. Living Image™ software provides a streamlined interface for image acquisition, analysis, and data export, making it straightforward to incorporate the IVIS imaging platform into established preclinical research workflows.
-
What reagents do I need to get started with in vivo optical imaging?
The reagents you need depend on your imaging modality. For in vivo bioluminescence imaging, you'll need a luciferase-expressing cell line or animal model along with a substrate such as IVISbrite D-luciferin. For in vivo fluorescence imaging, IVISense™ probes offer a broad selection of targeted and activatable fluorescent agents, labels, and dyes optimized for use with IVIS systems.
-
How do I ensure my optical imaging data is reproducible and publication-ready?
Reproducibility in optical imaging depends on consistent animal handling, standardized imaging parameters, and rigorous quantification practices. Best practices include:
- Using consistent anesthesia protocols and animal positioning
- Establishing defined regions of interest (ROIs) for quantification
- Normalizing data appropriately across imaging sessions
- Leveraging Living Image™ software's built-in tools for standardized analysis and data export
IVIS optical imaging systems are widely cited in peer-reviewed literature, and Revvity provides application notes and protocols to help support publication-quality data generation.
-
Is in vivo optical imaging suitable for my specific research application?
IVIS optical imaging supports a broad range of preclinical research applications, including:
- Oncology - tumor growth, metastasis tracking, and drug candidate response monitoring
- Immunology - immune cell trafficking and inflammatory response studies
- Infectious disease - pathogen tracking and host-pathogen interaction studies
- Neuroscience - reporter-based studies of neurological disease models
- Drug development - biodistribution, pharmacokinetics, and efficacy studies
If you're unsure whether in vivo optical imaging is the right fit for your model or experimental question, Revvity's application specialists are available to help you design your study.