Cellaca PLX High-throughput Image Cytometer

The Cellaca® PLX system with Matrix analysis software and dedicated reagents and consumables provides a benchtop solution for accurate measurements of small sample volumes to easily perform rapid subpopulation analysis for downstream processing.

For research use only. Not for use in diagnostic procedures.
Part Number: PLX-SYS1
  • The Cellaca PLX system with Matrix analysis software and dedicated reagents and consumables provides a benchtop solution for accurate measurements of small sample volumes to easily perform rapid subpopulation analysis for downstream processing.

    Multiplexing Made Easy

    The Cellaca PLX image cytometry system is easy to use, performing simple yet sensitive cell counts, viability readouts, and multiplex analysis in seconds.

    Small Sample Volume

    The sample-efficient Cellaca PLX requires between 15 – 50 uL per single sample analysis. That’s 10-30 times less sample volume required per test, compared to a flow cytometer.

    Speed with Sensitivity

    The time to downstream processing is shortened by multiplexing with four channels with viability readouts at one minute per sample.

    Optimized Assays and Kits

    Our simple-to-use, mix, incubate, wash, and read reagent kits provide immunophenotyping plus viability multiplexing assays using disposable, low fluorescence consumables.

    User-Friendly Software

    Optimized protocols streamline surface marker staining, vitality, and apoptosis analysis with step-by-step methodologies and customizable result presentations.

    Low Auto-Fluorescent Consumables

    Allow for accurate surface marker detection.

    Hardware, Instruments, and System Capabilities

    The Cellaca PLX’s ability to consistently image, de-cluster, and report cell counts, viability, concentration, and phenotyping data makes it a versatile instrument during every stage of cell line development. The Cellaca PLX allows labs to shorten the time to downstream processing by multiplexing with up to four channels to obtain critical viability readouts at one minute per sample with no warm-up time. The cell population data can then be viewed as a histogram, scatter plot, dot plot, or contour plot for easy data viewing and analysis.

    Whether using it as a complementary method for additional data or as the first stop before starting downstream assays, image cytometry can save laboratories time and prevent excessive sample loss. With this output speed, researchers can quickly perform cell purity checks at the bench and then easily continue with downstream assays without waiting for a flow cytometer. By performing multiplexing assays at the bench, laboratories can reduce the reliance on a busy flow core facility, saving flow cytometry for more complicated or detailed assays.

    Expert Support for Assay Development

    On-site, remote, and hybrid training are available to assist with initial setup and continued assay support for improved workflows.

    Remote and Field Serviceability

    Calibration-free instrumentation with minimal routine maintenance. No clogging or liquid waste stream.

    Automation Ready

    Compatible with robotic integration and automated liquid handling systems.

    21 CFR Part 11 Ready

    • Audit trails, time stamping, user access control, and electronic signatures.
    • File locking and change tracking.
    • Creation of new customizable defined roles with multiple configurations available
    • A close-looped database system to aid with data integrity and security.
    • Stress-Free Intuitive Software

    Built-in assays with optimized settings for over 400 individual cell types.

    Configurable data and calculation reports with graphs, images, charts, and tables for ease of information sharing.

    Low Auto-Fluorescent Consumables

    Cellaca PLX consumable slides provide a safe and self-contained environment for the sample which then does not require a decontamination procedure of the instrument at the end of each run. The slide holder, which is included with the instrument, can accommodate 4 slides or 8 samples per experimental run.

    Cellaca PLX Optimized Assay Reagents and Kits

    The Cellaca PLX system provides flow-like data with simple-to-use, mix, incubate, wash, and read reagent kits that provide immunophenotyping plus cell counts and viability multiplexing assays using disposable, low fluorescence consumables. Quickly perform cell counts, concentration, purity checks, and viability at the bench with Cellaca PLX immunophenotyping kits which combine CD3, CD4, and CD8 surface marker detection with cell viability in a single multiplex assay.

    Available assay kits include:

    • Immune cell Phenotyping
    • Apoptosis detection
    • High-throughput cell viability
    • Fluorescent protein analysis

    Cellaca PLX Applications

    With the Cellaca PLX Platform, you can:

    • Quickly perform cell purity checks and viability at the bench with Cellaca PLX immunophenotyping kits which combine CD3, CD4, and CD8 surface marker detection with cell viability in a single multiplex assay.
    • Stain transfected cell lines with viability dyes to determine the percentage of transfected or transduced cells that are live/dead.
    • Perform routine viability measurements as well as apoptosis functional assays to determine cell health.
  • Brand
    Cellaca

Resources

1-6 of 41 Resources
Application Note Icon Image
Application Note
A novel method for T-cell immunophenotyping using the Cellometer Spectrum image cytometer.
T-cell, immunophenotyping, Cellometer, Spectrum, image cytometry
Application Note Icon Image
Application Note
A novel NK-cell mediated cytotoxicity detection method using the Cellometer image cytometer.
Application note, NK-cell mediated cytotoxicity, cytotoxicity assay, Cellometer,
Application Note Icon Image
Application Note
Accurate cell counting for single cell sequencing platforms using the Cellometer K2 fluorescent cell counter.
cell counting, single cell sequencing, Cellometer K2, fluorescent cell counting
Application Note Icon Image
Application Note
An alternative image-based technique for phytoplankton cell counts in shellfish aquaculture.
cell imaging, phytoplankton, cell counting, shellfish, aquaculture, Cellometer, Auto T4
Application Note Icon Image
Application Note
Cell counting repeatability and consistency using the Cellometer Auto T4 brightfield cell counter.
Cell counting, repeatability, consistency, Cellometer Auto T4, Cellometer, Auto T4
Flyer
Cell counting: Are you using the right method?
cell counting, trypan blue, brightfield, fluorescent cell counting, AO/PI, AOPI