Skip to main content
Menu
US

HTRF Human Phospho-Aurora B (Thr232) Detection Kit, 500 Assay Points

This HTRF kit enables the cell-based quantitative detection of phosphorylated human Aurora B at Thr232.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Click to copy promo code to clipboard.
SAVE 15% NOW on online orders. Use promo code below.
YEAREND15
Offer valid until 12/15. Terms and conditions apply.
Feature Specification
Application Cell Signaling
Sample Volume 16 µL

This HTRF kit enables the cell-based quantitative detection of phosphorylated human Aurora B at Thr232.

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Click to copy promo code to clipboard.
SAVE 15% NOW on online orders. Use promo code below.
YEAREND15
Offer valid until 12/15. Terms and conditions apply.
Product Variants
Unit Size: 500 Assay Points
Part #:
64AURBT2PEG
List Price
USD 2,147.00
Unit Size: 10,000 Assay Points
Part #:
64AURBT2PEH
List Price
USD 12,490.00

Overview

This HTRF cell-based assay conveniently and accurately detects human Aurora B protein (related to the AURKB gene) ubiquitously expressed in eukaryotes. Aurora B belongs to the serine/threonine Aurora kinase family (including Aurora A and Aurora C), essential for cell division via mitosis regulation especially in the process of chromosomal segregation. It is activated through the autophosphorylation of Threonine 232 residue mainly occurring from the late S-Phase through the M phase during the cellular division cycle or DNA damage response. The overexpression of the Aurora kinases in a wide range of cancers (Leukemia, Colon Cancer, Prostate Cancer, and Breast Cancer) makes them interesting candidates for the development of Aurora kinase inhibitors (AKIs).

Specifications

Application
Cell Signaling
Brand
HTRF
Detection Modality
HTRF
Lysis Buffer Compatibility
Lysis Buffer 1
Lysis Buffer 4
Molecular Modification
Phosphorylation
Product Group
Kit
Sample Volume
16 µL
Shipping Conditions
Shipped in Dry Ice
Target Class
Phosphoproteins
Target Species
Human
Technology
TR-FRET
Unit Size
500 Assay Points

Video gallery

How it works

Phospho-Aurora B (Thr232) assay principle

The Phospho-Aurora B (Thr232) assay measures Aurora B when phosphorylated at Thr232. Unlike Western Blot, the assay is entirely plate-based and does not require gels, electrophoresis, or transfer. The Phospho-Aurora B (Thr232) assay uses 2 labeled antibodies: one with a donor fluorophore, the other with an acceptor. The first antibody was selected for its specific binding to the phosphorylated motif on the protein, the second for its ability to recognize the protein independent of its phosphorylation state. Protein phosphorylation enables an immune-complex formation involving both labeled antibodies and which brings the donor fluorophore into close proximity to the acceptor, thereby generating a FRET signal. Its intensity is directly proportional to the concentration of phosphorylated protein present in the sample, and provides a means of assessing the protein’s phosphorylation state under a no-wash assay format.

phospho-how-it-works-phospho-btk-tyr223-a1.svg

 

Phospho-Aurora B (Thr232) 2-plate assay protocol

The 2-plate protocol involves culturing cells in a 96-well plate before lysis, then transferring lysates into a 384-well low volume detection plate before adding Phospho-Aurora B (Thr232) HTRF detection reagents. This protocol enables the cells' viability and confluence to be monitored.

Two-plate protocol of the HTRF total BRD2 assay

 

Phospho-Aurora B (Thr232) 1-plate assay protocol

Detection of Phosphorylated Aurora B (Thr232) with HTRF reagents can be performed in a single plate used for culturing, stimulation, and lysis. No washing steps are required. This HTS designed protocol enables miniaturization while maintaining robust HTRF quality.

One-plate protocol of the HTRF total BRD2 assay

 

Assay validation

Activation of Total and Phospho-Aurora B (Thr232) measured on HeLa cells

HeLa cells (Immortalized Human cervical cancer cell line) were seeded in a 96-well culture-treated plate at 100,000 cells/well for 24 hours in complete culture medium for adhesion. After cell culture medium removal, they were treated with increasing concentrations of Nocodazole for 20h at 37 ° C, 5% CO2. After overnight treatment (20h), the cell culture medium was removed and 50 µl of supplemented Lysis Buffer#1 (1X) were dispensed into each well for 30 min at RT under gentle shaking. After cell lysis, 16 µL of lysates were transferred into a 384-well low volume white microplate and 4 µL of the HTRF Total Aurora B or Phospho-Aurora B (Thr232) detection antibodies were added. The HTRF signal was recorded after an overnight incubation.
 

Nocodazole is a microtubule destabilizer inducing a G2/M cell cycle arrest. It has been demonstrated that Nocodazole-treated cells show higher Aurora protein expression levels to overcome cell cycle arrest.
 

As expected, the results obtained show an increased level of Total and Thr232 Phosphorylated Aurora B proteins  upon treatment with Nocodazole.

1assay-validation-aurora-b-phospho-pharmaco-1.svg

 

Inhibitor characterization with Phospho-Aurora B (Thr232) and Total Aurora B on HeLa cells

HeLa cells (Immortalized Human cervical cancer cell line) were seeded in a 96-well culture-treated plate at 100,000 cells/well for 24 hours in complete culture medium for adhesion. After cell culture medium removal, they were treated with increasing concentrations of inhibitors (Tozasertib or Alisertib) co-incubated with a fixed concentration of Nocodazole at 200 nM for 20h at 37 ° C, 5% CO2, in cell culture medium containing 5% SVF. After overnight treatment, the cell culture medium was removed and 50 µl of supplemented Lysis Buffer#1 (1X) were dispensed into each well for 30 min at RT under gentle shaking. After cell lysis, 16 µL of lysates were transferred into a 384-well low volume white microplate and 4 µL of the HTRF Total Aurora B or Phospho-Aurora B (Thr232) detection antibodies were added. The HTRF signal was recorded after an overnight incubation.
 

The 3 compounds have been described in the literature for their inhibitory effect on phosphorylated Aurora B (thr232), reaching a 96% maximum inhibition, without impacting the total protein level [2,3,4].
 

As expected, the results obtained show a clear dose-dependent inhibition of Aurora B phosphorylation at Thr232 upon treatment with Tozasertib or Alisertib, while the Aurora B protein expression level remains constant.

 

[2] : Sells et al. ACS Med.Chem.Lett.,2015

[3] : Tyler et al. Cell cycle,2007

[4] :  Qi et al. Leuk Res,2013

2assay-validation-aurora-b-phospho-pharmaco-2-1.svg
3assay-validation-aurora-b-phospho-pharmaco-2-2.svg
Inhibitor profiling Aurora A Vs Aurora B
4assay-validation-aurora-b-phospho-pharmaco-3-1.svg
5assay-validation-aurora-b-phospho-pharmaco-3-2.svg

HeLa cells (Immortalized Human cervical cancer cell line) were seeded in a 96-well culture-treated plate at 100,000 cells/well for 24 hours in complete culture medium for adhesion. After cell culture medium removal, they were treated with increasing concentrations of inhibitors ( MLN8054, Tozasertib, or Alisertib) co-incubated with a fixed concentration of Nocodazole at 200 nM for 20h at 37 ° C, 5% CO2, in cell culture medium containing 5% SVF. After overnight treatment, the cell culture medium was removed and 50 µl of supplemented Lysis Buffer#1 (1X) were dispensed into each well for 30 min at RT under gentle shaking. After cell lysis, 16 µL of lysates were transferred into a 384-well low volume white microplate and 4 µL of the HTRF Total Aurora A (#64AURATPEG/H),  Phospho-Aurora A (Thr288) (#64AURAT2PEG/H), Total Aurora B (#64AURBTPEG/H) or Phospho-Aurora B (Thr232) detection antibodies were added. The HTRF signal was recorded after an overnight incubation.

The results indicate an inhibitor dose-dependent phosphorylation decrease with the expected selectivity behavior [2,3,4,5]:

  • Tozasertib is an Aurora A and Aurora B  pan inhibitor.
  • Alisertib is 20-fold more selective for Aurora A than for Aurora B.
  • MLN8054 is a highly selective Aurora A inhibitor (no inhibition of Aurora B Thr232 phosphorylation, at least at 1µM).

The Aurora A and Aurora B protein expression levels remain constant (data not shown).

 

[2] : Manfredi et al. PNAS,2006; [3] : Sells et al. ACS Med.Chem.Lett.,2015; [4] : Tyler et al. Cell cycle,2007; [5] :  Qi et al. Leuk Res,2013

6assay-validation-aurora-b-phospho-pharmaco-4.svg
Specificity and selectivity of HTRF Phospho-Aurora B (Thr232) assay using gene silencing (SiRNA)

HeLa cells were treated with 25 nM of SMARTPool ON-TARGETplus siRNA (Horizon) specifically targeting Aurora A (#L-003545-01-0005), Aurora B (# L-003326-00-0005), and Aurora C (#L-019573-00-0005), or with a non-targeting siRNA (# D-001810-10-20, included as control), in a 96-well plate (25,000 cells/well) under 100 µL for 24H. After cell culture medium removal, cells were stimulated by adding 300 nM Nocodazole in complete cell culture medium for an additional 24h-incubation at 37°C, 5% CO2. After medium removal, cells were lysed with 50 µL lysis buffer #1 (1X) for 30 min at RT under gentle shaking, and 16 µL of lysates were transferred into a low volume white microplate before the addition of 4 µL of premixed HTRF Phospho-Aurora B detection antibodies. The HTRF signal was recorded after an overnight incubation at RT.
 

Cell treatment with Aurora B siRNA led to a significant downregulation of Phospho-Aurora B,  with a 64% signal decrease compared to the cells transfected with the non-targeting siRNA.

Despite high homology between the 3 family proteins, no decrease in signal was observed for cells treated with Aurora A or Aurora C siRNA, demonstrating the specificity and selectivity of the kit.

7assay-validation-aurora-b-phospho-pharmaco-5.svg

 

Validation on various Human cell lines

The HTRF Phospho-Aurora B (Thr232) assay efficiently detects endogenous phosphorylated Aurora B protein in various human cellular models expressing different levels of the protein.

8assay-validation-aurora-b-phospho-pharmaco-6.svg

 

HTRF Phospho-Aurora B (Thr232) assay compared to Western Blot

HeLa cells were cultured in a T175 flask in complete culture medium at 37°C, 5% CO2. After a 24H incubation, the cells were first stimulated with Nocodazole 300 nM for 20H, 37°C, 5% CO2, then lysed with 3 mL of supplemented lysis buffer #1 (1X) for 30 minutes at RT under gentle shaking.

Serial dilutions of the cell lysate were performed using supplemented lysis buffer, and 16 µL of each dilution were transferred into a low volume white microplate before the addition of 4 µL of Phospho-Aurora B (Thr232) detection reagents. Equal amounts of lysates were used for a side by side comparison between HTRF and Western Blot.
 

A side by side comparison of Western Blot and HTRF demonstrates that the HTRF assay is 16-fold more sensitive than the Western Blot, at least under these experimental conditions.

 

9assay-validation-aurora-b-phospho-pharmaco-7.png

Resources

Are you looking for resources, click on the resource type to explore further.

1-2 of 2 Resources
Brochure Icon
Brochure
HTRF assays and reagents catalog

Discover the versatility and precision of Homogeneous Time-Resolved Fluorescence (HTRF) technology. Our HTRF portfolio offers a...

Guide Icon
Guide
HTRF solutions, guide to major applications

This guide provides you an overview of HTRF applications in several therapeutic areas.

Scroll Icon