Skip to main content

AlphaLISA Human CD80 Detection Kit, 5,000 Assay Points

The AlphaLISA® immunoassay kit for human CD80 enables the quantitative determination of human cluster of differentiation 80 (CD80) in serum, buffered solution, and cell culture media using a homogeneous AlphaLISA assay (no wash steps).

For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption & disposal requirements under European REACH regulations (EC 1907/2006).
Part Number: AL3055HV
Unit Size:
Part Number: AL3055C
Unit Size:
Part Number: AL3055F
Unit Size:
  • Formats:

    • Our 100 assay point kit allows you to run 100 wells in 96-well format, using a 100 µL reaction volume (10 µL of sample).
    • Our 500 assay point kit allows you to run 500 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).
    • Our 5,000 assay point kit allows you to run 5,000 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).

    Features:

    • No-wash steps, no separation steps
    • ELISA alternative technology
    • Sensitive detection
    • Broad sample compatibility
    • Small sample volume
    • Results in less than 3 hours
    • Half the time of an ELISA assay

    AlphaLISA technology allows the detection of molecules of interest in buffer, cell culture media, serum and plasma in a highly sensitive, quantitative, reproducible and user-friendly mode. In an AlphaLISA assay, a Biotinylated Anti-Analyte Antibody binds to the Streptavidin-coated Alpha Donor beads, while another Anti-Analyte Antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads provokes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.

    Cluster of differentiation 80 (CD80), also known as B7-1, is a protein that is activated by the binding of CD28 or CTLA-4, providing a costimulatory signal necessary for T cell activation and survival. This protein is expressed on dendritic cells, macrophages, and activated B cells. It has been shown that CD80 and CD86 can substitute for one another in the initial activation of resting CD4(+) T cells as well as the maintenance of their proliferative response. Studies show that increased levels of CD80 in urinary excretion have been linked to Fabry disease, and Minimal Change Disease. This kit is designed to detect and quantify the levels of CD80 in cell culture supernatant and serum.

  • Application
    Protein Analysis & Detection
    Assay Points
    5000
    Assay Target Class
    Biomarker
    Protein
    Automation Compatible
    Yes
    Brand
    AlphaLISA
    Detection Method
    Alpha
    Therapeutic Area
    Oncology

Resources

1-2 of 2 Resources
Application Note Icon Image
Application Note
Protocol Optimization for Detection and Quantification of Membrane-Bound Proteins Using AlphaLISA Te
alphalisa, cell surface, membrane protein, detection
Flyer
Reagent solutions for autoimmunity research.
alphalisa, alpha, htrf, surefire, autoimmunity, flyer