Skip to main content

AlphaLISA SureFire Biotin-Free Human and Mouse Total XIAP Detection Kit, 500 Assay Points

The AlphaLISA™ SureFire® Biotin-Free Human and Mouse Total XIAP assay is a sandwich immunoassay for quantitative detection of total XIAP in cellular lysates using Alpha Technology.

Feature Specification
Application Cell Signaling
Protocol Time 2h at RT
Sample Volume 10 µL

The AlphaLISA™ SureFire® Biotin-Free Human and Mouse Total XIAP assay is a sandwich immunoassay for quantitative detection of total XIAP in cellular lysates using Alpha Technology.

Product variants
Compare all
Remove all
Add to compare Add to compare
Remove
Unit Size: 100 Assay Points
Part #:
ASBF-TXIAP-A-HV
List price
USD 737.00
Your price:
Add to compare Add to compare
Remove
Unit Size: 500 Assay Points
Part #:
ASBF-TXIAP-A500
List price
USD 2,490.00
Your price:
Add to compare Add to compare
Remove
Unit Size: 10,000 Assay Points
Part #:
ASBF-TXIAP-A10K
List price
USD 14,982.00
Your price:
Add to compare Add to compare
Remove
Unit Size: 50,000 Assay Points
Part #:
ASBF-TXIAP-A50K
List price
USD 47,624.00
Your price:
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).

Loading...

Overview

X-Linked Inhibitor of Apoptosis (XIAP) is a member of the inhibitor of apoptosis (IAP) protein family that functions as a potent endogenous inhibitor of caspase-3, caspase-7, and caspase-9, thereby suppressing apoptotic cell death. XIAP binds directly to these caspases through its baculovirus IAP repeat (BIR) domains, blocking their proteolytic activity and preventing the cleavage of cellular substrates that would otherwise lead to apoptosis. XIAP is frequently overexpressed in various cancer types, including leukemia, lymphoma, and solid tumors, and its upregulation is associated with increased resistance to chemotherapy, radiation, and other apoptosis-inducing stimuli. Conversely, downregulation or inhibition of XIAP can sensitize cancer cells to apoptosis, making it an attractive therapeutic target. Small-molecule XIAP antagonists that disrupt the XIAP-caspase interaction are in clinical development for the treatment of hematological malignancies and solid tumors. Quantitative assessment of XIAP expression levels can provide insights into the apoptotic threshold of cancer cells and guide the selection of appropriate XIAP-targeting strategies.

The AlphaLISA SureFire Biotin-Free Human and Mouse Total XIAP Detection Kit is a sandwich immunoassay for the quantitative detection of total XIAP in cellular lysates, using Alpha Technology.

Formats:

  • The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 μL reaction volume.
  • The 500-point kit contains enough reagents to run 500 wells in 384-well format, using a 20 μL reaction volume.
  • The 10,000-point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 μL reaction volume.
  • The 50,000-point kit contains enough reagents to run 50,000 wells in 384-well format, using a 20 μL reaction volume.

AlphaLISA SureFire Biotin Free kits are compatible with:

  • Cell and tissue lysates
  • Antibody modulators
  • Biotherapeutic antibodies
  • Biotin rich samples

AlphaLISA SureFire Biotin Free kits can be used for:

  • Cellular kinase assays
  • Receptor activation studies
  • High-throughput screening for preclinical studies

How it works

Total-AlphaLISA SureFire Biotin Free assay principle

The Total-AlphaLISA SureFire Biotin Free assay measures the expression level of a target protein in a biological sample (e.g. cell lysate).

The Total-AlphaLISA SureFire Biotin Free assay uses two antibodies which recognize two different distal epitopes on the target protein. AlphaLISA assays require two bead types: Acceptor and Donor Beads. Acceptor Beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor Beads are coated with a proprietary CaptSure3 agent to capture one of the detection antibodies, which is labeled with the CaptSure3 tag. In the presence of target protein, the two antibodies bring the Donor and Acceptor Beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor Bead, allowing for the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.

Total-AlphaLISA SureFire Ultra Biotin Free assay principle

 

Total-AlphaLISA SureFire Biotin Free two-plate assay protocol

The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA SureFire Biotin Free detection reagents. This protocol enables cell viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.

2 plates assay protocol alphalisa surefire ultra biotin free total assay

Total-AlphaLISA SureFire Biotin Free one-plate assay protocol

Detection of Total target protein with AlphaLISA SureFire Biotin Free reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining robust AlphaLISA SureFire quality.

1 plate assay protocol alphalisa surefire ultra biotin free total assay

Assay validation

RIPK2 inhibitor blocks activation of the NOD2 signalling pathway

THP-1 cells were seeded in a 96-well plate (400,000 cells/well) in complete medium and were left untreated or treated with 5 µM WEHI-345 (RIPK2 inhibitor) for 2 hours and further stimulated with 200 ng/mL L18-MDP (NOD2 agonist) for 30 minutes.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). RIPK2, XIAP Total as well as IKKb (Ser177/181) and NFkB (Ser536) Phospho levels were evaluated using respective AlphaLISA SureFireassay. For the detection step, 10 µL of cell lysate (approximately 40,000 cells or 8,000 cells for XIAP and NFkB) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, treatment with WEHI-345 resulted in inhibition of NOD2 pathway activation with no changes in RIPK2 and XIAP Total levels.

RIPK2 inhibitor blocks activation of the NOD2 signalling pathway

Assay versatility

XIAP Total levels in human PBMCs

Peripheral Blood Mononuclear Cells (PBMCs) were isolated from healthy donors using Ficoll Plaque Plus (Merck GE17-1440-02). Cells were lysed at 4 x 106 cells/mL with Lysis Buffer for 10 minutes at RT with shaking. Lysate was serially diluted and XIAP Total levels were evaluated using the AlphaLISA SureFireBiotin Freeassay.

For the detection step, 10 µL of cell lysate were transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

Approximate number of cells/datapoint is indicated on the graph. The assay can detect XIAP in less than 2,000 cells.

XIAP Total levels in human PBMCs

XIAP expression in various cell lines

Adherent cells were cultured to confluence in T175 flasks at 37°C, 5% CO2 and lysed with Lysis Buffer at a density of 2 x 106 cells/mL. Suspension cells were harvested and lysed with Lysis Buffer at a density of 1.6 x 106 cells/mL.

XIAP levels were evaluated using the AlphaLISA SureFireBiotin Freeassay. For the detection step, 10 µL of cell lysate (approximately 20,000 adherent or 16,000 suspension cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

Variable levels of basal XIAP were observed across various cell lines.

Assay validation (cell panel) of TXNIP Total assay

Assay sensitivity

Assay sensitivity - cell lysate dilution

Cell lysate was prepared from THP-1 cells lysed to a final density of 5 x 106 cells/mL in Lysis Buffer.

Lysates were serially diluted and XIAP levels were evaluated using the AlphaLISA SureFireBiotin Free kit. For the detection step, 10 µL of lysate was transferred into a 384-well white OptiPlate, followed by 5 µL Acceptor mix and incubated for 1 hour at room temperature. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

Approximate number of cells/datapoint is indicated on the graph. The dotted line represents assay background. The assay can detect XIAP in less than 200 cells.

Assay sensitivity – cell lysate dilution

Specifications

Application
Cell Signaling
Automation Compatible
Yes
Brand
AlphaLISA SureFire Biotin-Free
Detection Modality
Alpha
Product Group
Kit
Protocol Time
2h at RT
Sample Volume
10 µL
Shipping Conditions
Shipped in Blue Ice
Target
XIAP
Target Class
Phosphoproteins
Target Species
Human
Mouse
Technology
Alpha
Therapeutic Area
Inflammation
Oncology
Unit Size
500 Assay Points

Resources

Are you looking for resources, click on the resource type to explore further.

1-1 of 1 Resources
Guide Icon
Guide
AlphaLISA SureFire Ultra: the ultimate guide for successful experiments

The definitive guide for setting up a successful AlphaLISA SureFire Ultra assay

Several biological processes are regulated by...

Loading...

Revvity AI Assistant Beta

Scroll Icon