The AlphaLISA™ SureFire® Biotin-Free Human and Mouse Total XIAP assay is a sandwich immunoassay for quantitative detection of total XIAP in cellular lysates using Alpha Technology.
| Feature | Specification |
|---|---|
| Application | Cell Signaling |
| Protocol Time | 2h at RT |
| Sample Volume | 30 µL |
The AlphaLISA™ SureFire® Biotin-Free Human and Mouse Total XIAP assay is a sandwich immunoassay for quantitative detection of total XIAP in cellular lysates using Alpha Technology.
Loading...
X-Linked Inhibitor of Apoptosis (XIAP) is a member of the inhibitor of apoptosis (IAP) protein family that functions as a potent endogenous inhibitor of caspase-3, caspase-7, and caspase-9, thereby suppressing apoptotic cell death. XIAP binds directly to these caspases through its baculovirus IAP repeat (BIR) domains, blocking their proteolytic activity and preventing the cleavage of cellular substrates that would otherwise lead to apoptosis. XIAP is frequently overexpressed in various cancer types, including leukemia, lymphoma, and solid tumors, and its upregulation is associated with increased resistance to chemotherapy, radiation, and other apoptosis-inducing stimuli. Conversely, downregulation or inhibition of XIAP can sensitize cancer cells to apoptosis, making it an attractive therapeutic target. Small-molecule XIAP antagonists that disrupt the XIAP-caspase interaction are in clinical development for the treatment of hematological malignancies and solid tumors. Quantitative assessment of XIAP expression levels can provide insights into the apoptotic threshold of cancer cells and guide the selection of appropriate XIAP-targeting strategies.
The AlphaLISA SureFire Biotin-Free Human and Mouse Total XIAP Detection Kit is a sandwich immunoassay for the quantitative detection of total XIAP in cellular lysates, using Alpha Technology.
Formats:
AlphaLISA SureFire Biotin Free kits are compatible with:
AlphaLISA SureFire Biotin Free kits can be used for:
The Total-AlphaLISA SureFire Biotin Free assay measures the expression level of a target protein in a biological sample (e.g. cell lysate).
The Total-AlphaLISA SureFire Biotin Free assay uses two antibodies which recognize two different distal epitopes on the target protein. AlphaLISA assays require two bead types: Acceptor and Donor Beads. Acceptor Beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor Beads are coated with a proprietary CaptSure3 agent to capture one of the detection antibodies, which is labeled with the CaptSure3 tag. In the presence of target protein, the two antibodies bring the Donor and Acceptor Beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor Bead, allowing for the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.
The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA SureFire Biotin Free detection reagents. This protocol enables cell viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.
Detection of Total target protein with AlphaLISA SureFire Biotin Free reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining robust AlphaLISA SureFire quality.
THP-1 cells were seeded in a 96-well plate (400,000 cells/well) in complete medium and were left untreated or treated with 5 µM WEHI-345 (RIPK2 inhibitor) for 2 hours and further stimulated with 200 ng/mL L18-MDP (NOD2 agonist) for 30 minutes.
After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). RIPK2, XIAP Total as well as IKKb (Ser177/181) and NFkB (Ser536) Phospho levels were evaluated using respective AlphaLISA SureFireassay. For the detection step, 10 µL of cell lysate (approximately 40,000 cells or 8,000 cells for XIAP and NFkB) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.
As expected, treatment with WEHI-345 resulted in inhibition of NOD2 pathway activation with no changes in RIPK2 and XIAP Total levels.
Peripheral Blood Mononuclear Cells (PBMCs) were isolated from healthy donors using Ficoll Plaque Plus (Merck GE17-1440-02). Cells were lysed at 4 x 106 cells/mL with Lysis Buffer for 10 minutes at RT with shaking. Lysate was serially diluted and XIAP Total levels were evaluated using the AlphaLISA SureFireBiotin Freeassay.
For the detection step, 10 µL of cell lysate were transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.
Approximate number of cells/datapoint is indicated on the graph. The assay can detect XIAP in less than 2,000 cells.
Adherent cells were cultured to confluence in T175 flasks at 37°C, 5% CO2 and lysed with Lysis Buffer at a density of 2 x 106 cells/mL. Suspension cells were harvested and lysed with Lysis Buffer at a density of 1.6 x 106 cells/mL.
XIAP levels were evaluated using the AlphaLISA SureFireBiotin Freeassay. For the detection step, 10 µL of cell lysate (approximately 20,000 adherent or 16,000 suspension cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.
Variable levels of basal XIAP were observed across various cell lines.
Cell lysate was prepared from THP-1 cells lysed to a final density of 5 x 106 cells/mL in Lysis Buffer.
Lysates were serially diluted and XIAP levels were evaluated using the AlphaLISA SureFireBiotin Free kit. For the detection step, 10 µL of lysate was transferred into a 384-well white OptiPlate, followed by 5 µL Acceptor mix and incubated for 1 hour at room temperature. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.
Approximate number of cells/datapoint is indicated on the graph. The dotted line represents assay background. The assay can detect XIAP in less than 200 cells.
| Application |
Cell Signaling
|
|---|---|
| Automation Compatible |
Yes
|
| Brand |
AlphaLISA SureFire Biotin-Free
|
| Detection Modality |
Alpha
|
| Product Group |
Kit
|
| Protocol Time |
2h at RT
|
| Sample Volume |
30 µL
|
| Shipping Conditions |
Shipped in Blue Ice
|
| Target |
XIAP
|
| Target Class |
Phosphoproteins
|
| Target Species |
Human
Mouse
|
| Technology |
Alpha
|
| Therapeutic Area |
Inflammation
Oncology
|
| Unit Size |
100 Assay Points
|
Are you looking for resources, click on the resource type to explore further.
Alpha technolgy enables the rapid and straightforward mesaure of virtually any target. This includes enzymes, receptor-ligand...
The definitive guide for setting up a successful AlphaLISA SureFire Ultra assay
Several biological processes are regulated by...
Discover Alpha SureFire® Ultra™ assays, the no-wash cellular kinase assays leveraging Revvity's exclusive bead-based technology...
This document includes detailed tables listing HTRF™, AlphaLISA™ SureFire® Ultra™, and Alpha SureFire® Ultra™ Multiplex assays...
Loading...
We are here to answer your questions.