The LANCE® Ultra Human IL-8 Detection Kit is designed for detection and quantitation of human interleukin 8 in cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Protein Quantification |
Dynamic Range | 8.8 - 30,000 pg/mL |
Limit of Detection | 8.8 pg/mL |
Limit of Quantification | 44.4 pg/mL |
Sample Volume | 15 µL |
The LANCE® Ultra Human IL-8 Detection Kit is designed for detection and quantitation of human interleukin 8 in cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
The LANCE Ultra Human IL-8 Detection Kit is designed for detection and quantitation of human interleukin 8 in cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
The 500 point kit contains enough reagents to run 500 wells in 384-well format, using a 20 µL reaction volume (15 µL of sample). The 10,000 point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 µL reaction volume (15 µL of sample).
LANCE and LANCE (Lanthanide chelate excite) Ultra are our TR-FRET (time-resolved fluorescence resonance energy transfer), homogeneous (no wash) technologies. One antibody of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second molecule is labeled with an acceptor fluorophore (ULight™ dye). Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm.
Interleukin 8 (IL8 or CXCL8), a member of the ELR+ CXC chemokine family, is a 8.4 kDa polypeptide that forms homodimers in vivo. IL8 is secreted by several types of cells: fibroblasts, monocytes, macrophages and endothelial cells, among many others, in response to inflammatory stimuli. It is a chemoattractant and activator for neutrophils, directing them from periferal blood to the site of inflammation. It is also a potent angiogenic factor promoting endothelial and epithelial migration and proliferation in several cancers, and is associated with metastasis. It signals through two specific G protein-coupled receptors, CXCR1 and CXCR2, sharing ~77% identity.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Brand |
LANCE Ultra
|
Detection Modality |
LANCE
|
Dynamic Range |
8.8 - 30,000 pg/mL
|
Limit of Detection |
8.8 pg/mL
|
Limit of Quantification |
44.4 pg/mL
|
Product Group |
Kit
|
Sample Volume |
15 µL
|
Shipping Conditions |
Shipped in Blue Ice
|
Target |
IL8
|
Target Class |
Cytokines
|
Target Species |
Human
|
Technology |
TR-FRET
|
Therapeutic Area |
Inflammation
|
Unit Size |
500 Assay Points
|