The AlphaLISA™ Human Matrix Metalloproteinase-1 (MMP1) Detection Kit is designed for detection and quantitation of human MMP1 in serum, buffered solution or cell culture medium in a homogeneous (no-wash steps, no separation steps) assay. The kit was designed to detect both MMP1 and pro-MMP1.
Feature | Specification |
---|---|
Application | Protein Quantification |
Dynamic Range | 82.6 - 300,000 pg/mL |
Limit of Detection | 82.6 pg/mL |
Sample Volume | 5 µL |
The AlphaLISA™ Human Matrix Metalloproteinase-1 (MMP1) Detection Kit is designed for detection and quantitation of human MMP1 in serum, buffered solution or cell culture medium in a homogeneous (no-wash steps, no separation steps) assay. The kit was designed to detect both MMP1 and pro-MMP1.
Formats:
Features:
Matrix Metalloproteinase-1 (MMP1) is a 52 kDa, zinc- and calcium-dependent, endopeptidase expressed by fibroblasts, keratinocytes, endothelial cells, monocytes and macrophages. MMP1 is secreted as a pro-enzyme (pro-MMP1) and is activated by proteolytic cleavage by serine proteases such as plasmin. MMP1 is involved in the breakdown of all the components of the extracellular matrix during embryonic development, reproduction, and tissue remodeling. In normal conditions, MMP1 participates in tissue remodeling, blood vessel formation, and bone development. The expression level and activity of MMP1 is frequently deregulated in several diseases, cancer and rheumatoid arthritis in particular.
AlphaLISA technology allows the detection of molecules of interest in a no-wash, highly sensitive, quantitative assay. In an AlphaLISA assay, a biotinylated anti-analyte antibody binds to the Streptavidin-coated Donor beads while another anti-analyte antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads causes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Brand |
AlphaLISA
|
Detection Modality |
Alpha
|
Dynamic Range |
82.6 - 300,000 pg/mL
|
Limit of Detection |
82.6 pg/mL
|
Product Group |
Kit
|
Sample Volume |
5 µL
|
Shipping Conditions |
Shipped in Blue Ice
|
Target |
MMP1
|
Target Class |
Biomarkers
|
Target Species |
Human
|
Technology |
Alpha
|
Therapeutic Area |
Oncology
|
Unit Size |
500 assay points
|
Are you looking for resources, click on the resource type to explore further.
We are here to answer your questions.