The AlphaLISA™ Human Adiponectin Detection Kit is designed for detection and quantitation of human adiponectin in serum, buffered solution or cell culture medium in a homogeneous (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Feature | Specification |
---|---|
Application | Protein Quantification |
Dynamic Range | 45 - 1,000,000 pg/mL |
Limit of Detection | 45 pg/mL |
Sample Volume | 5 µL |
The AlphaLISA™ Human Adiponectin Detection Kit is designed for detection and quantitation of human adiponectin in serum, buffered solution or cell culture medium in a homogeneous (no-wash steps, no separation steps) assay.
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Formats:
Features:
Adiponectin (Acrp30, in mouse) is a hormone secreted by differentiated adipocytes that regulates energy homeostasis and glucose and lipid metabolism. It is expressed as a ~35 kDa protein. It has been demonstrated that Adiponectin / Acrp30 plays a major role in controlling whole-body metabolism, particularly by enhancing insulin sensitivity in muscle and liver, and by augmenting the oxydation of fatty acids in muscle.
AlphaLISA technology allows the detection of molecules of interest in a no-wash, highly sensitive, quantitative assay. In an AlphaLISA assay, a biotinylated anti-analyte antibody binds to the Streptavidin-coated Donor beads while another anti-analyte antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads causes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.
Application |
Protein Quantification
|
---|---|
Automation Compatible |
Yes
|
Brand |
AlphaLISA
|
Detection Modality |
Alpha
|
Dynamic Range |
45 - 1,000,000 pg/mL
|
Host Species |
Human
|
Limit of Detection |
45 pg/mL
|
Product Group |
Kit
|
Sample Volume |
5 µL
|
Shipping Conditions |
Shipped in Blue Ice
|
Target |
Adiponectin
|
Target Class |
Biomarkers
|
Target Species |
Human
|
Technology |
Alpha
|
Therapeutic Area |
Metabolic
|
Unit Size |
500 Assay Points
|