| Feature | Specification |
|---|---|
| Application | Protein Quantification |
| Dynamic Range | 44.8- 30,000 pg/mL |
| Limit of Detection | 44.8 pg/mL |
| Limit of Quantification | 234.4 pg/mL |
| Sample Volume | 15 µL |
Loading...
The LANCE Ultra human IL-6 Detection Kit is designed for detection and quantitation of human interleukin-6 in cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
The 500 point kit contains enough reagents to run 500 wells in 384-well format, using a 20 µL reaction volume (15 µL of sample). The 10,000 point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 µL reaction volume (15 µL of sample).
LANCE and LANCE (Lanthanide chelate excite) Ultra are our TR-FRET (time-resolved fluorescence resonance energy transfer), homogeneous (no wash) technologies. One antibody of interest is labeled with a donor fluorophore (a LANCE Europium chelate) and the second molecule is labeled with an acceptor fluorophore (ULight™ dye). Upon excitation at 320 or 340 nm, energy can be transferred from the donor Europium chelate to the acceptor fluorophore if sufficiently close for FRET (~10 nm). This results in the emission of light at 665 nm.
Interleukin 6 (IL-6) is a ~22 kDa pleiotropic cytokine that acts not only on the immune system, but also affects many physiological events in various organs. IL6 exerts pro- or anti-inflammatory effects, depending on the target cell analyzed and the in vivo environmental circumstances. IL-6 is a differentiation and proliferation factor for B and T cells, and acts as a migration factor on monocytic cells. It is the major activator of acute-phase protein expression in the liver, a hematopoietic factor, and acts as a survival factor on neuronal cells. IL-6 signals through binding to the gp130/ IL-6R receptor complex, leading to the activation of JAK/STAT, MAPK and PI3K cascades.
| Application |
Protein Quantification
|
|---|---|
| Automation Compatible |
Yes
|
| Brand |
LANCE Ultra
|
| Detection Modality |
LANCE
|
| Dynamic Range |
44.8- 30,000 pg/mL
|
| Limit of Detection |
44.8 pg/mL
|
| Limit of Quantification |
234.4 pg/mL
|
| Product Group |
Kit
|
| Sample Volume |
15 µL
|
| Shipping Conditions |
Shipped in Blue Ice
|
| Target |
IL6
|
| Target Class |
Cytokines
|
| Target Species |
Human
|
| Technology |
TR-FRET
|
| Therapeutic Area |
Inflammation
|
| Unit Size |
10,000 assay points
|