Skip to main content
Menu

AlphaLISA SureFire Ultra Human and Mouse Total MEK1 Detection Kit, 50,000 Assay Points

The AlphaLISA™ SureFire® Ultra™ Total MEK1 assay is a sandwich immunoassay for quantitative detection of MEK1 (both phosphorylated and non-phosphorylated) in cellular lysates using Alpha Technology. This assay is intended to be used as a normalization for phosphorylation studies.

Feature Specification
Application Cell Signaling
Sample Volume 10 µL

The AlphaLISA™ SureFire® Ultra™ Total MEK1 assay is a sandwich immunoassay for quantitative detection of MEK1 (both phosphorylated and non-phosphorylated) in cellular lysates using Alpha Technology. This assay is intended to be used as a normalization for phosphorylation studies.

Product variants
Unit Size: 500 assay points
Part #:
ALSU-TMEK1-A500
List price
USD 2,441.00
Your online price:
Unit Size: 10,000 assay points
Part #:
ALSU-TMEK1-A10K
List price
USD 14,688.00
Your online price:
Unit Size: 50,000 assay points
Part #:
ALSU-TMEK1-A50K
List price
USD 46,690.00
Your online price:
Unit Size: 100 assay points
Part #:
ALSU-TMEK1-A-HV
List price
USD 722.00
Your online price:
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption, and disposal requirements under European REACH regulations (EC 1907/2006).

Loading...

Overview

The AlphaLISA™ SureFire® Ultra™ Total MEK1 assay is a sandwich immunoassay for quantitative detection of MEK1 (both phosphorylated and non-phosphorylated) in cellular lysates using Alpha Technology. This assay is intended to be used as a normalization for phosphorylation studies.

The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 µL reaction volume. The 500 point kit contains reagents to run 500 wells in 384-well format, using a 20 µL reaction volume. The 10,000 point kit contains reagents to run 10,000 wells in 384-well format, using a 20 µL reaction volume. The 50,000 point kit contains reagents to run 500 wells in 384-well format, using a 20 µL reaction volume.

In the AlphaLISA™ SureFire® Ultra™ assay, Donor beads are coated with streptavidin to capture one of the antibodies, which is biotinylated. Acceptor beads are coated with a proprietary CaptSure™ agent that immobilizes the other antibody, labeled with a CaptSure™ tag. In the presence of target protein, the two antibodies bring the Donor and Acceptor beads close together, generating signal. The amount of light emission is directly proportional to the amount of protein present in the sample.

AlphaLISA™ SureFire® Ultra™ kits are compatible with:

  • Cell and tissue lysates
  • Antibody modulators
  • Biotherapeutic antibodies

Alpha SureFire® kits can be used for:

  • Cellular kinase assays
  • Receptor activation studies
  • Screening

How it works

Total-AlphaLISA SureFire Ultra assay principle

The Total-AlphaLISA SureFire Ultra assay measures the expression level of a protein target in a cell lysate.

The Total-AlphaLISA SureFire Ultra assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor beads are coated with streptavidin to capture one of the detection antibodies, which is biotinylated. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.

assay-principle-Total-AlphaLISA-Surefire-Ultra.jpg

 

Total-AlphaLISA SureFire Ultra two-plate assay protocol

The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA SureFire Ultra detection reagents. This protocol permits the cells viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.

2 plates assay protocol AlphaLISA Surefire Ultra Total assay

Total-AlphaLISA SureFire Ultra one-plate assay protocol

Detection of Total target protein with AlphaLISA SureFire Ultra reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining AlphaLISA SureFire Ultra quality.

1-plate-assay-protocol-AlphaLISA-Surefire-Ultra-Total-assay

Assay validation

Validation of MEK1 Total in Neuregulin1 treated cells

MCF7 cells were seeded in a 96-well plate (40,000 cells/well) in complete medium, and incubated overnight at 37°C, 5% CO2. The cells were treated with increasing concentrations of Neuregulin1 (NRG1) for 10 minutes.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). Phospho (Ser218/222) and Total MEK1 levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, NRG1 triggered a dose-dependent increase in the levels of Phospho (Ser218/222) MEK1 while Total levels remained unchanged.

Validation of MEK1 Total in Neuregulin1 treated cells

Validation of MEK1 Total in EGF treated cells

HEK293 cells were seeded in a 96-well plate (30,000 cells/well) in complete medium, and incubated for 48 hours at 37°C, 5% CO2. The cells were starved for 2 hours and treated with increasing concentrations of EGF for 10 minutes.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). Phospho (Ser218/222) and Total MEK1 levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 6,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, EGF triggered a dose-dependent increase in the levels of Phospho (Ser218/222) MEK1 while Total levels remained unchanged.

Validation of MEK1 Total in EGF treated cells

Validation of MEK1 Total in Anti-CD3 treated cells

Jurkat cells were seeded in a 96-well plate (50,000 cells/well) in HBSS + 0.1% BSA. The cells were starved for 60 minutes and then treated with increasing concentrations of Anti-CD3 antibody for 5 minutes.

After treatment, the cells were lysed with the addition of 50 µL of 5X Lysis Buffer for 10 minutes at RT with shaking (350 rpm). Phospho (Ser218/222) and Total MEK1 levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 2,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, Anti-CD3 triggered a dose-dependent increase in the levels of Phospho (Ser218/222) MEK1 while Total levels remained unchanged.

Validation of MEK1 Total in Anti-CD3 treated cells

Validation of MEK1 Total in AG1478 treated cells

A431 cells were seeded in a 96-well plate (20,000 cells/well) in complete medium and incubated for 48 hours at 37°C, 5% CO2. The cells were treated with increasing concentrations of AG1478 for 2 hours and then treated with 1 ng/mL EGF for 30 minutes.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). Phospho (Ser218/222) and Total MEK1 levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, AG1478 triggered a dose-dependent decrease in the levels of Phospho (Ser218/222) MEK1 stimulated by EGF, while Total levels remained unchanged.

Validation of MEK1 Total in AG1478 treated cells

Validation of MEK1 Total in AMG-510 treated cells

SW1573 cells were seeded in a 96-well plate (40,000 cells/well) in complete medium, and incubated overnight at 37°C, 5% CO2. The cells were treated with increasing concentrations of AMG-510 for 2 hours.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). Phospho (Ser218/222) and Total MEK1 levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, AMG-510, a KRASG12C inhibitor, triggered a dose-dependent decrease in the levels of Phospho (Ser218/222) MEK1 while Total levels remained unchanged.

Validation of MEK1 Total in AMG-510 treated cells

Assay specificity/selectivity

MEK1 Total assay specificity

Specificity of the MEK1 Total assay was assessed by using active MEK1 and MEK2 recombinant proteins.

Dilutions of recombinant MEK1 (Abcam, ab63209) and MEK2 (Merck, SLBN1818V) proteins were prepared in Lysis Buffer and evaluated using the AlphaLISA SureFire Ultra assay.

For the detection step, 10 µL of diluted protein was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

The MEK1 Total assay showed reactivity only to MEK1 protein, no cross reactivity to MEK2 protein was observed. The dotted line represents assay background.

MEK1 Total Assay specificity

Assay versatility

Versatility of MEK1 Total assay in various cell lines

Adherent cells were grown to confluency in a T175 flask at 37°C, 5% CO2, and were lysed with Lysis Buffer at a density of 0.5 x 106 cells/mL. Suspension cells were harvested, washed in HBSS and lysed with Lysis Buffer at 1.6 x 106 cells/mL.

Total MEK1 levels were evaluated using the AlphaLISA SureFire Ultra assay. For the detection step, 10 µL of cell lysate (5,000 adherent and 16,000 suspension cells) were transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

Total MEK1 expression was detected in a wide range of human and mouse cell lines.

Versatility of MEK1 Total assay in various cell lines

Assay sensitivity

MEK1 assay sensitivity - cell lysate dilution

Cell lysate was prepared from A431 cells cultured to confluence in T175 flasks in complete medium. Cells were treated with 200 ng/mL EGF for 10 minutes and then lysed in 10 mL of Lysis Buffer.

Lysate was serially diluted in Lysis Buffer and assayed for Phospho (Ser218/222) and Total MEK1 using respective AlphaLISA SureFire Ultra kits. For the detection step, 10 µL of lysate was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at room temperature. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

Approximate number of cells/datapoint is indicated on the graph. The dotted line represents assay background. This assay can detect MEK1 expression in less than 200 cells/datapoint.

Assay Sensitivity - Cell lysate

Specifications

Application
Cell Signaling
Automation Compatible
Yes
Brand
AlphaLISA SureFire Ultra
Cellular or Signaling Pathway
MAPK
Detection Modality
Alpha
Host Species
Human
Lysis Buffer Compatibility
Lysis Buffer
Molecular Modification
Total
Product Group
Kit
Sample Volume
10 µL
Shipping Conditions
Shipped in Blue Ice
Target
MEK1
Target Class
Phosphoproteins
Target Species
Human
Mouse
Technology
Alpha
Unit Size
50,000 assay points

Video gallery

Resources

Are you looking for resources, click on the resource type to explore further.

1-5 of 5 Resources
Guide Icon
Guide
AlphaLISA SureFire Ultra assay optimization

This guide outlines further possible optimization of cellular and immunoassay parameters to ensure the best possible results are...

Guide Icon
Guide
AlphaLISA SureFire Ultra: the ultimate guide for successful experiments

The definitive guide for setting up a successful AlphaLISA SureFire Ultra assay

Several biological processes are regulated by...

Brochure Icon
Brochure
Alpha SureFire Ultra no-wash immunoassay catalog

Discover Alpha SureFire® Ultra™ assays, the no-wash cellular kinase assays leveraging Revvity's exclusive bead-based technology...

Application Note Icon
Application Note
Characterizing chemokine receptor inhibitors with AlphaLISA SureFire Ultra, Alpha SureFire Ultra Multiplex and LANCE Ultra cAMP assays

The measurement of protein phosphorylation is a useful tool for measuring the modulation of receptor activation by both antibodies...

Brochure Icon
Brochure
Species compatibility for HTRF, AlphaLISA SureFire Ultra and Alpha SureFire Ultra Multiplex assays

This document includes detailed tables listing HTRF™, AlphaLISA™ SureFire® Ultra™, and Alpha SureFire® Ultra™ Multiplex assays...

Loading...

Scroll Icon

Revvity AI Assistant Beta