View All
| Feature | Specification |
|---|---|
| Application | Cell Signaling |
| Sample Volume | 10 µL |
STAT6 (Signal Transducer and Activator of Transcription 6) is a crucial transcription factor in the JAK/STAT signaling pathway. In both humans and mice, STAT6 is encoded by a single gene and plays a central role in various cellular processes, particularly in immune regulation, T helper 2 (Th2) cell differentiation, and allergic responses. While the activation state of STAT6 is often of interest, measuring total STAT6 levels is equally important for understanding the overall regulation and expression of this critical signaling protein. STAT6 signaling is frequently implicated in various diseases, especially in allergic disorders, asthma, and certain types of cancer, where alterations in STAT6 expression or activity can contribute to disease progression, immune dysregulation, and therapy resistance.
The AlphaLISA SureFire Ultra Human and Mouse Total STAT6 Detection Kit is a sandwich immunoassay designed for the quantitative detection of total STAT6 protein levels in cellular lysates from both human and mouse samples, using Alpha technology.
The Total-AlphaLISA SureFire Ultra assay measures the expression level of a protein target in a cell lysate.
The Total-AlphaLISA SureFire Ultra assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor beads are coated with streptavidin to capture one of the detection antibodies, which is biotinylated. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.
The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA SureFire Ultra detection reagents. This protocol permits the cells viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.
Detection of Total target protein with AlphaLISA SureFire Ultra reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining AlphaLISA SureFire Ultra quality.
PBMCs were isolated from healthy donors and cultured for 6 days in complete DMEM containing 20 ng/mL M-CSF to differentiate them into macrophages. Macrophages were seeded in a 96-well plate (20,000 cells/well) in complete DMEM, and incubated overnight at 37°C, 5% CO2. Cells were treated with the indicated concentration of IL-4 for 20 minutes.
After treatment, cells were lysed in 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). STAT6 Phospho (Tyr641) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 2,000 cells) were transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark.
As expected, IL-4 triggered a dose-dependent increase in the levels of Phospho STAT6 (Tyr641) while Total STAT6 levels remained unchanged.
THP-1 cells were seeded in a 96-well plate (400,000 cells/well) in HBSS + 0.1 % BSA and treated with increasing concentrations of IL-4 for 20 minutes.
After treatment, the cells were lysed with the addition of 50 µL of 5X Lysis Buffer for 10 minutes at RT with shaking (350 rpm). STAT6 Phospho (Tyr641) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 16,000 cells/datapoint) were transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.
As expected, IL-4 triggered a dose-dependent increase in the levels of STAT6 Phospho Tyr641 while Total STAT6 levels remained unchanged.
HeLa cells were seeded in a 96-well plate (40,000 cells/well) in complete medium and incubated overnight at 37°C, 5% CO2. The cells were treated with increasing concentrations of IL-4 for 20 minutes.
After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). STAT6 Total and Phospho (Tyr641) levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.
As expected, IL-4 triggered a dose-dependent increase in the levels of Phospho STAT6 (Tyr641) while Total STAT6 levels remained unchanged.
| Application |
Cell Signaling
|
|---|---|
| Automation Compatible |
Yes
|
| Brand |
AlphaLISA SureFire Ultra
|
| Detection Modality |
Alpha
|
| Lysis Buffer Compatibility |
Lysis Buffer
|
| Molecular Modification |
Total
|
| Product Group |
Kit
|
| Sample Volume |
10 µL
|
| Shipping Conditions |
Shipped in Blue Ice
|
| Target |
STAT6
|
| Target Class |
Phosphoproteins
|
| Target Species |
Human
Mouse
|
| Technology |
Alpha
|
| Therapeutic Area |
Autoimmunity
Immuno-oncology
Inflammation
|
| Unit Size |
10,000 assay points
|
Are you looking for resources, click on the resource type to explore further.
This guide outlines further possible optimization of cellular and immunoassay parameters to ensure the best possible results are...
The definitive guide for setting up a successful AlphaLISA SureFire Ultra assay
Several biological processes are regulated by...
Discover Alpha SureFire® Ultra™ assays, the no-wash cellular kinase assays leveraging Revvity's exclusive bead-based technology...
The measurement of protein phosphorylation is a useful tool for measuring the modulation of receptor activation by both antibodies...
This document includes detailed tables listing HTRF™, AlphaLISA™ SureFire® Ultra™, and Alpha SureFire® Ultra™ Multiplex assays...
Loading...
We are here to answer your questions.