The DNA 5K / RNA / Charge Variant Assay LabChip (bulk value 4 pack) is designed for use with the LabChip HT DNA 5K assay, the HT RNA assay, the LabChip Charge Variant assay, the RNA Pico assay and the LabChip Small RNA assay. It can be used with both the HT LabChip GX and LabChip GXII Touch systems. It can be used to analyze up to 2,000 samples/chip. It contains 4 chips.
If using LabChip software newer than the V1.9 version, use the High pI Charge Variant LabChip (P/N CLS153419) for charge variant analysis instead.
| Feature | Specification |
|---|---|
| Analytical Sensitivity | DNA 0.25 ng/µL, Pico RNA 250 pg/µL Total RNA, Small RNA 50 pg/μL, 500 pg/µL mRNA |
| Application |
DNA Analysis Protein Analysis RNA Analysis |
| Linear Concentration Range | DNA 0.25 - 50 ng/µL 0.2 per fragment, RNA 25 - 250 ng/ μL (Std Sens) and 5 - 50 ng/μL (High Sens), Pico RNA 500 - 5,000 pg/µL Total RNA 625 - 5000 pg/µL mRNA, small RNA 100-10,000 pg/ul, Protein 25 µL with concentration between 0.5 - 10 mg/mL |
| Sample Type |
DNA Protein RNA |
| Size Range | DNA 100 - 5,000 bp, RNA 100 - 6,000 nt, Small RNA 20 - 150 nt |
| Sizing Precision RSD (CV) | DNA ± 10%, small RNA CV < 5.0% or 4 nt, Protein CV < 5% for varying concentration from 1 - 3 mg/mL CV < 3% at constant concentration |
| Sizing Resolution | DNA ± 10% from 150 - 500 bp ± 15% from 100 - 150 bp, 500 - 1500 bp ± 20% from 1500 - 5000 bp, Protein Comparable to IEX and conventional CZE |
| Feature | Specification |
|---|---|
| Analytical Sensitivity | DNA 0.25 ng/µL, Pico RNA 250 pg/µL Total RNA, Small RNA 50 pg/μL, 500 pg/µL mRNA |
| Application |
DNA Analysis Protein Analysis RNA Analysis |
| Linear Concentration Range | DNA 0.25 - 50 ng/µL 0.2 per fragment, RNA 25 - 250 ng/ μL (Std Sens) and 5 - 50 ng/μL (High Sens), Pico RNA 500 - 5,000 pg/µL Total RNA 625 - 5000 pg/µL mRNA, small RNA 100-10,000 pg/ul, Protein 25 µL with concentration between 0.5 - 10 mg/mL |
| Sample Type |
DNA Protein RNA |
| Size Range | DNA 100 - 5,000 bp, RNA 100 - 6,000 nt, Small RNA 20 - 150 nt |
| Sizing Precision RSD (CV) | DNA ± 10%, small RNA CV < 5.0% or 4 nt, Protein CV < 5% for varying concentration from 1 - 3 mg/mL CV < 3% at constant concentration |
| Sizing Resolution | DNA ± 10% from 150 - 500 bp ± 15% from 100 - 150 bp, 500 - 1500 bp ± 20% from 1500 - 5000 bp, Protein Comparable to IEX and conventional CZE |
The DNA 5K / RNA / Charge Variant Assay LabChip (bulk value 4 pack) supports a variety of samples workflows, providing a fast and easy way to analyze DNA, RNA, and to perform charge variant analysis of monoclonal antibody (mAb) samples (if using V1.9 software or older version).
Note: If using newer software, use the High pI Charge Variant LabChip (P/N CLS153419) for charge variant analysis instead.
Chip reusability
The DNA 5K / RNA / Charge Variant Assay LabChip (bulk value 4 pack) can be reused multiple times enabling the analysis of up to 2,000 samples/chip on the HT LabChip GX/GXII Touch instruments. Chips are prepped once per day and can be reused on multiple days to lower your per sample costs.
Automated chip priming
The LabChip GX/GXII Touch instruments automate the tedious, labor-intensive chip priming and sample loading required with other systems, enabling a walk-away workflow, greatly reducing hands-on time.
| Analytical Sensitivity |
DNA 0.25 ng/µL, Pico RNA 250 pg/µL Total RNA, Small RNA 50 pg/μL, 500 pg/µL mRNA
|
|---|---|
| Application |
DNA Analysis
Protein Analysis
RNA Analysis
|
| Automation Compatible |
Yes
|
| Instrument Compatibility |
LabChip GXII Touch
LabChip GX Touch
|
| Linear Concentration Range |
DNA 0.25 - 50 ng/µL 0.2 per fragment, RNA 25 - 250 ng/ μL (Std Sens) and 5 - 50 ng/μL (High Sens), Pico RNA 500 - 5,000 pg/µL Total RNA 625 - 5000 pg/µL mRNA, small RNA 100-10,000 pg/ul, Protein 25 µL with concentration between 0.5 - 10 mg/mL
|
| Sample Type |
DNA
Protein
RNA
|
| Sample Volume |
DNA 2 μL, RNA 2 μL RNA Std Sens or 6 μL RNA High Sens. Pico RNA 2 μL, Small RNA 2 μL, Protein 25 μL
|
| Size Range |
DNA 100 - 5,000 bp, RNA 100 - 6,000 nt, Small RNA 20 - 150 nt
|
| Sizing Precision RSD (CV) |
DNA ± 10%, small RNA CV < 5.0% or 4 nt, Protein CV < 5% for varying concentration from 1 - 3 mg/mL CV < 3% at constant concentration
|
| Shipping Conditions |
Shipped in Blue Ice Soft
|
| Sizing Resolution |
DNA ± 10% from 150 - 500 bp ± 15% from 100 - 150 bp, 500 - 1500 bp ± 20% from 1500 - 5000 bp, Protein Comparable to IEX and conventional CZE
|
| Storage Conditions |
4°C
|
| Technology |
Microfluidic Electrophoresis
|
| Unit Size |
4 chips
|