Skip to main content
Menu

LabChip High Resolution Chip

The LabChip™ High Resolution Chip is compatible with the LabChip Glycan Profiling Assay Reagent Kit and LabChip Protein Low Molecular Weight Assay. These assays are designed to be run on the LabChip GXII Touch™ Protein Characterization System.

This chip is available in a single pack.

Product variants
Capacity: Batch size up to 96 samples
Instrument Compatibility
LabChip GXII Touch HT
Part #:
760524
List price
USD 1,446.61
Your online price:
Capacity: Batch size 48 samples or less
Instrument Compatibility
LabChip GXII Touch 24
Part #:
CLS138951
List price
USD 886.56
Your online price:
For research use only. Not for use in diagnostic procedures.
Feature Specification
Application Protein Analysis
Linear Concentration Range LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type Glycan
Protein
Size Range LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV) LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Sizing Resolution LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Unit Size 1 chip
Feature Specification
Application Protein Analysis
Linear Concentration Range LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type Glycan
Protein
Size Range LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV) LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Sizing Resolution LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Unit Size 1 chip

Overview

The LabChip High Resolution Chip can be used to run up to 400 samples for sample batch sizes of up to 96 samples for high throughput analysis or up to 48 samples for low throughput analysis using the LabChip Glycan Profiling and Protein Low Molecular Weight Assay on the LabChip GXII Touch HT protein characterization system.

Note the LabChip High Resolution Chip 24 is available for use with smaller batch sizes.

Chip reusability

The LabChip High Resolution Chip can be reused multiple times, enabling the analysis of up to 400 samples on the LabChip GXII Touch HT instrument. Chips are prepped once per day and can be reused through multiple preps to lower your per sample costs

Automated chip priming

The LabChip GXII Touch instrument automates the tedious, labor-intensive chip priming and sample loading required with other systems, enabling a walk-away workflow, greatly reducing hands-on time.

Specifications

Capacity
Batch size up to 96 samples
Application
Protein Analysis
Automation Compatible
Yes
Instrument Compatibility
LabChip GXII Touch HT
Linear Concentration Range
LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility
LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type
Glycan
Protein
Sample Volume
LMW Protein 2 µL, Glycan 8µL
Size Range
LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV)
LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Shipping Conditions
Shipped in Blue Ice Soft
Sizing Resolution
LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Technology
Microfluidic Electrophoresis
Unit Size
1 chip

Resources

Are you looking for resources, click on the resource type to explore further.

1-1 of 1 Resources
Product Note Icon
Product Note
Automated characterization of proteins and nucleic acids

Read the LabChip® GXII Touch protein characterization system product note to learn about an automated alternative to traditional...

Loading...

Scroll Icon

Revvity AI Assistant Beta