Skip to main content
Menu
reimagining immunoassay workflow
Flyer

Immunoassay platforms to fit every need

Discover our range of immunoassay technologies that enable the selection of optimal immunoassay platforms for your requirements. Choose from traditional wash-based assays to homogenous kits and toolboxes, including our AlphaLISA, HTRF, DELFIA, LANCE TR-FRET, and ELISA solutions.

Immunoassay technologies

Immunoassay technologies graph

The right technology choice for successful assays

  ELISA DELFIA HTRF and LANCE Ultra AlphaLISA
Browse products ELISA products DELFIA products HTRF products

LANCE Ultra products
AlphaLISA products
Plate format 96-wells 96 to 384-wells Anywhere from 96- to 1536-wells Anywhere from 96- to 1536-wells
Miniaturization Limited Limited Yes Yes
Time to results 4-24 hr 4-6 hr 1-2 hr 1-2 hr
Significant time saving reallocated back to science
Wash steps Yes Yes No No
While timely, in some instances wash steps can be beneficial. Wash steps may become necessary to remove non-bound analytes with higher cross-reactivity profiles and to decrease background Absence of wash steps increases throughput, results in ease of use, reduces time to results and lowers variability
Dynamic range 2 Log 5 Log 4 Log 5 Log
Large dynamic ranges are beneficial to avoid making extremely large dilutions during sample preparation. Large sample dilution are cumbersome and lead to analytical imprecision/variability
Sensitivity 10 pg/mL 10 pg/mL 10 pg/mL 1 pg/mL
Sufficient sensitivity to assay in serum, fluid, cell supernatant & lysates Sufficient sensitivity to assay in cell supernatant & lysates Sufficient sensitivity to assay in cell supernatant & lysates. May lend itself to diluting then testing serum samples, due to its superior sensitivity
Avidity No No Only with stretavidin Yes
Avidity may be a sought after characteristic when detecting protein-protein interactions of low affinities
Signal stability Up to 1 hr Days - Years 24 hrs to days 24 hrs to days
Allows for the plates to be left on the bench and read at a convenient time. Maximizes assay precision when incubation times vary
Multiplexing No Yes (up to 3 targets) No Yes (up to 3 targets)
Reader requirements Chromogenic and Chemiluminescence Compatible TRF Compatible TR-FRET Compatible Alpha Compatible
100+ compatible reader 50+ compatible reader 10+ compatible reader
Chemistry Enzyme-linked, HRP or AP Fluorophore Chelate Fluorophore Chelate (LANCE Ultra) and Fluorophore Cryptate (HTRF) Fluorophore Embedded Beads
Extremely robust chemistry, light & temperature insensitive Extremely robust chemistry, light, temperature. Ion insensitive (HTRF only)
Analyte size No limitation No limitation Subject to forster radius (9 nm) Subject to singlet oxygen diffusion (200 nm)
Although LANCE, HTRF and Alpha are subject to forster radius and singlet oxygen diffusion laws, these requirements are rarely a limitation to the development of a successful assay