Skip to main content
Menu
US
Cell Counting and Image Cytometry

High-Throughput Counting Of GFP-Expressing Influenza Viral Foci-1

Section
Modern Virology Assays
Celigo Applications
Cell Counting Method Selection
Cell Counting and Image Cytometry FAQs
Cell-based Assays for Bioprocessing
Cell-based Assays for Gene Therapy Development
Cellometer Applications
Modern Virology Assays
Sub Section
Viral Titre
Antibody Binding Inhibition
Antibody Neutralization
Cytopathic Effects
Viral Titre
Topic
High-Throughput Counting Of GFP-Expressing Influenza Viral Foci-1
Direct Counting of Individual Infected Cells
High-Throughput Counting Of GFP-Expressing Influenza Viral Foci-1
Influenza Viral Titration With mKate2 Fluorescent Protein Reporter
Zika Viral Titration with mKate2 Fluorescent Protein Reporter
Automated Counting of Plaques

High-throughput counting of GFP-expressing influenza viral foci for focus formation assay in 96-well plates

The Celigo™ image cytometer can be used to count and analyze fluorescent or colorimetric foci. The foci are generated when the target virus do not induce lysing of the host cells. These foci can be detected by using fluorescent viral particles, fluorescent immunostaining, and immunostaining with horseradish peroxidase (HRP). These foci images are typically captured manually using a fluorescent microscope and analyzed using an external image analysis software such as Image.

In this work, the GFP-expressing influenza virus was grown under an overlay of methylcellulose and media, thus enabling the formation of tight fluorescent foci. The viral solutions were diluted from 300 ffu/well to 4.7 ffu/well in 2-fold dilutions, where a negative control was also prepared without any virus. The Vero cells were infected with the GFP-expressing influenza virus for 31 hours and fixed before image cytometric analysis.

The Celigo image cytometer automatically acquired and analyzed whole well fluorescent images for 96-well plates, generating the number of foci per well. Brightfield and fluorescent images can be captured and analyzed in less than 10 min/plate, equivalent to 50 plates/day when integrated with automation.

High-throughput counting of GFP-expressing influenza viral foci-1
High-throughput counting of GFP-expressing influenza viral foci-2

Whole well brightfield and fluorescent overlay image, as well as zoomed-in fluorescent image showing the cluster for fluorescent foci

Below are examples of influenza viral titers with different quantities of fluorescent foci generated in each well. These fluorescent foci are directly counted in the images, which can be used to generate a viral titer plot to better characterize viral infection.

High-throughput counting of GFP-expressing influenza viral foci-3

Whole well and zoomed-in fluorescent images of the viral titer at different dilution of the virus for the viral titer assay

High-throughput counting of GFP-expressing influenza viral foci-4

Foci counting results in respect to the focus forming units (FFU) infecting the Vero cells

For research use only. Not for use in diagnostic procedures.

ON THIS PAGE