Tuberculosis (TB) testing is often discussed in terms of accuracy and clinical results. But an important part of the testing process happens before a blood sample ever reaches the laboratory.
From tube selection and sample volume to transport conditions and processing time, the way blood is collected and handled can influence the reliability of interferon-gamma release assays (IGRAs). Understanding these variables can help healthcare providers and laboratories simplify workflows, reduce avoidable errors, and support more consistent testing.
Key takeaways:
-
Sample collection matters. Tube requirements, blood volume, mixing, and processing conditions can introduce variability into TB testing.
-
Not all IGRA workflows are the same. Different methods place different requirements on the collection site and laboratory.
-
Standardized procedures help reduce risk. Clear collection and handling protocols can minimize preventable errors, repeat blood draws, and delays.
-
The T-SPOT™.TB test method simplifies collection. A single standard blood tube* per patient reduces collection complexity, while antigen stimulation takes place in the lab.
Identifying TB infection before it progresses
Tuberculosis remains the world's leading cause of death from a single infectious agent. An estimated one-quarter of the global population is infected with Mycobacterium tuberculosis, although most infected individuals do not develop active disease (1). Identifying TB infection before it progresses to active disease is an important part of TB prevention, particularly for patients preparing to receive immunosuppressive therapies.
IGRAs are blood tests used to detect TB infection by measuring the immune response to TB-specific antigens. Unlike the traditional tuberculin skin test (TST), IGRAs are not affected by prior Bacille Calmette-Guérin (BCG) vaccination (2). While these tests offer important clinical advantages, their performance also depends on appropriate sample collection and handling.
Where variability enters the testing process
Blood collection may seem like a routine first step, but different IGRA methods have different requirements that can affect the testing workflow.
Several factors deserve attention:
- Blood volume: Some testing methods require samples to be collected within specified volume ranges. Incorrect fill volumes can affect testing or lead to sample rejection.
- Tube handling: Depending on the method, appropriate mixing is necessary to ensure contact between blood and test reagents.
- Processing time: Delays between collection and laboratory processing can introduce variability.
- Sample identification: Accurate labeling and tracking are essential to maintaining sample integrity throughout the testing process.
These factors become especially important when blood is collected across multiple sites, including outpatient clinics, physician offices, and community healthcare facilities. For laboratories receiving samples from numerous collection locations, consistent procedures and clear communication with phlebotomy teams are essential.
Why the timing of antigen stimulation matters
One important difference between IGRA methods is where and when antigen stimulation occurs.
Some IGRA formats use collection tubes containing TB-specific antigens. In these workflows, stimulation begins following blood collection, making correct tube filling, mixing, and handling important parts of the collection-site procedure. Other approaches collect blood in standard tubes and perform antigen stimulation after the sample reaches the laboratory.
This distinction affects how responsibilities are divided between collection personnel and laboratory staff.
When stimulation takes place in the laboratory, the lab can manage the timing and conditions of that step within its established procedures. Collection-site requirements may also be simpler.
Understanding these differences helps laboratories evaluate which testing workflow best fits their staffing, collection locations, and transportation arrangements (3).
What collection requirements mean for patients
The consequences of sample handling errors extend beyond the laboratory. When a specimen cannot be processed because of a collection or handling issue, the patient may need another blood draw. That can create additional appointments, inconvenience, and delays in obtaining information needed for clinical decisions.
These challenges may be particularly significant when TB screening is required before initiating biologic or immunosuppressive treatment.
Simplifying collection procedures and standardizing sample handling can help healthcare organizations reduce opportunities for preventable mistakes. However, simpler collection alone does not guarantee better results. Appropriate procedures, staff training, and adherence to assay-specific requirements remain essential.
Five questions to ask when evaluating a TB testing workflow
For healthcare organizations reviewing their IGRA testing procedures, several practical questions can help identify potential challenges:
- What collection tubes and supplies are required?
- How precisely must blood volume be controlled?
- What handling and mixing procedures must collection staff follow?
- What transport conditions and processing timelines apply?
- Where does antigen stimulation occur, and who is responsible for controlling that step?
Considering these questions can help laboratories and healthcare providers select a testing approach that aligns with their existing infrastructure and patient needs.
Putting these principles into practice
One example of a laboratory-centered approach is the T-SPOT.TB test method.
The test generally requires a single standard blood collection tube per patient*, with antigen stimulation performed in the laboratory rather than in antigen-containing collection tubes at the draw site. This approach can simplify collection-site requirements while allowing the laboratory to control important processing steps.
As with any IGRA, laboratories must follow the specific collection, transport, and processing requirements for the test.
Better testing begins with better workflows
Reliable TB testing depends on more than the analytical performance of an assay. Every step, from collecting and identifying the sample to transporting and processing it, contributes to the overall testing process.
By understanding where variability can occur and selecting procedures that fit their operations, healthcare organizations can support more consistent testing while reducing avoidable burdens on staff and patients.
Interested in a laboratory-centered approach to TB testing? Learn how the T-SPOT.TB test method supports a simplified blood collection workflow.
References
- World Health Organization. Global Tuberculosis Report 2025. https://www.who.int/teams/global-programme-on-tuberculosis-and-lung-health/tb-reports/global-tuberculosis-report-2025
- Centers for Disease Control and Prevention. Clinical Testing and Diagnosis for Tuberculosis. https://www.cdc.gov/tb/hcp/testing-diagnosis/index.html
- Banaei, N., Gaur, R. L. & Pai, M. Interferon gamma release assays for latent tuberculosis: What are the sources of variability? Journal of Clinical Microbiology. 54, 845-850 (2016).
*In immunosuppressed individuals, two tubes may be requested.
For in vitro diagnostic use. This product is only available where licensed in accordance with the law. Please contact your local representative for availability.
Revvity Inc. does not endorse or make recommendations with respect to research, medication, or treatments. All information presented is for informational purposes only and is not intended as medical advice. For country-specific recommendations, please consult your local healthcare professionals.